Be sure to use the right size extension cord. If cord size is wrong, tool may be
damaged. Tool performance may also be affected.

Extension Cord Size Requirement
1 to 25 feet, use 16 AWG rated cord
26 to 50 feet, use 14 AWG rated cord

Inspect extension cords often and replace if damaged.

Extension Cords

Loading Tool

Figure 2

Figure 3

Figure 1

Trigger Lock In
Off Position

1. Move trigger lock to the OFF

position (see Figure 1) and
unplug tool.

2. Turn tool upside down.
3. Press in latch lock and slide

staple chamber cover back
until fully open (see Figures
2 and 3).

Staple
Chamber
Cover

Latch
Lock

WARNING: Never load tool while it is plugged in. Accidental

discharge may occur. Before loading, move trigger lock to the OFF
position and unplug tool.

CAUTION: Use only extension cords marked for outdoor use.