Drolet DB03505 User Manual

Page 8

Advertising
background image

7

1.3

CLEARANCES


Clearances to any combustibles when measured directly from the floor protector to the ceiling must be a
minimum of 84" (2134 mm). Clearances to any combustibles when measured directly from the front of the
stove must be a minimum of 48" (1219 mm). The stove must also be placed so as to maintain the minimum
clearances to combustible walls specified for each type of connector used. See Table 1.3 below for all
clearance measures. Refer to Figure 1.3 for a diagram of each of the measures A through C.

Single walled connector

Listed double walled

connector

Unit:

To sidewall (A)

15" (381 mm)

15" (381 mm)

To back wall (B)

16" (406 mm)

10" (254 mm)

To corner

(C)

9" (229 mm)

9" (229 mm)

TABLE 1.3

Clearances to combustible materials


FIGURE 1.3 Clearances to combustible materials










Advertising