Environmental concerns, Dbk34a – specifications, Caution – Measurement Computing DBK34A User Manual
Page 6

Environmental Concerns
CAUTION
DBK34A Gel-Pack batteries contain toxic materials (Pb and H
2
SO
4
). At the end of
the battery life cycle the Gel-Packs must be recycled or properly disposed of.
DBK34A – Specifications
Name/Function: UPS / Battery Module
Battery Type: sealed-lead gel-pack
Number of Battery Packs: 2
Battery Pack Configuration: 6 series-connected D cells
Output Voltage: 12 V or 24 V (set by jumpers on TB1)
Output Fuses: F2 and F3; one 7.5 A fuse for each internal gel-pack battery
Input Fuses: F1: 7.5 A for auxiliary battery, F4: 15 A for input overload
Battery Capacity (Amp-Hours):
5 A-hr in 12 V mode (parallel)
2.5 A-hr in 24 V mode (series)
Operating Temperature: -20°F to 122°F (-29°C to 50°C)
Size: 8½ × 11 × 1¾ in. ( 216 × 279 × 44 mm)
Weight: 7.2 lb (3.27 kg)
DBK34A, pg. 6
879795