Operating heater, Continued, Variable control operation – Desa CGD3018 User Manual

Page 18

Advertising
background image

111160-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

18

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Press in and turn control knob clockwise

Clockwise

to the

HI position.

2.

Turn control knob clockwise

Clockwise

to the pilot position.

3.

Press in control knob and turn clockwise

Clockwise

to the

OFF position.

Shutting Off Burner(s) Only (pilot stays lit)

1.

Turn control knob clockwise

Clockwise

to the HI position.

2.

Press in and turn control knob clockwise

Clockwise

to the

pilot position.

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

The variable control valve can be set to any heat setting and
flame height desired, by simply turning the control knob until
that setting is attained. Even the lowest setting provides realis-
tic, dancing yellow flames. Selecting higher settings produces
greater heat output. This results in increased heating comfort.

VARIABLE CONTROL

OPERATION

WARNING: Do not operate heater between PILOT

and HI positions.

6.

With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the burner.
If needed, keep pressing ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service

person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure,
page 19.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. If control

knob does not pop out when released, contact a qualified
service person or gas supplier for repairs.

8.

Slightly depress and turn control knob counterclockwise

C-clockwise

to desired heating level. The burner(s) should light.

Set control knob to any heat level between HI and LO.

Figure 35 - Control Knob and Ignitor Button Location

PILOT

OFF

LO

HI

Ignitor Button

Note:

Home owners generally prefer to operate their heater

with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater

has been running.

Control Knob

1.

STOP! Read the safety information in column 2, page 17.

2.

Make sure equipment shutoff valve is fully open.

3.

Press in and turn control knob clockwise

Clockwise

to the

OFF position.

4.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, column 2 on page 17. If
you don’t smell gas, go to the next step.

5.

Slightly depress and turn control knob counterclockwise

C-clockwise

to the PILOT position. Press in control knob for five

(5) seconds (see Figure 35).

Note:

You may be running this heater for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.

Figure 36 - Pilot

Thermocouple

Pilot Burner

Ignitor
Electrode

OPERATING HEATER (Manually Controlled Models)

Lighting Instructions (Cont.)
Variable Control Operations
To Turn Gas Off to Appliance

OPERATING HEATER

Continued