Front panel layout

-1

00

-9

0

-80

-70

-60 -50

-40

-30

level[dBm]

accu

ok

lo

ad

field strength meter

FM614

Acc. check

Mod.

Charge

AC-line

Accu

on

off

Piezo

Handling of FM614

a) Mode of operation

Use switch "Accu / AC-line" to choose one of the modes accu or AC-supply.

b) Charging

The accumulators are charged whenever the FM614 is plugged to the AC-
power-supply. LED "Charge" indicates this status.

c) Checking the capacity

By pressing key "Acc. check" the status of capacity is indicated by the analog
display. With the help of the marking it is possible to recognize if the accus have
to be charged. The antenna shouldn't be connected to carry out this test.

d) Measurement of field strength

The antenna AI01 has to be connected to the input of FM614 by using the
coaxial cable to perform this test. By varying the position of the antenna or the
alignment to the transmitter, the maximum of field strength can be found.
Besides a high field strength the flashing of the LED "Mod." exactly in rythm of
the timing marks is important. This marks can be observed acoustic by a piezo
buzzer.