Generated Time codes

Besides the amplitude modulated sine wave signal, the board also provides unmodulated
DC-Level Shift TTL output in parallel. Thus six time codes are available.

a) B002:

100pps, PWM DC signal, no carrier
BCD time of year

b) B122:

100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time of year

c) B003:

100pps, PWM DC signal, no carrier
BCD time of year, SBS time of day

d) B123:

100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time of year, SBS time of day

e) B006:

100pps, PWM DC signal, no carrier
BCD time of year, year number ( 0...99 )

f) B126:

100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time of year, year number ( 0...99 )

g) B007:

100pps, PWM DC signal, no carrier
BCD time of year, SBS time of day, year number ( 0...99 )

h) B127:

100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time of year, SBS time of day, year number ( 0...99 )

i)

AFNOR:

Code according to NFS-87500, 100pps,
AM sine wave signal, 1kHz carrier frequency,
BCD time of year, complete date, SBS time-of-day,
Signal level according to NFS-87500

j)

IEEE1344:

Code according to IEEE1344-1995, 100pps,
AM sine wave signal, 1kHz carrier frequency,
BCD time-of-year, SBS time of day, IEEE1344

extensions for date, timezone, daylight-saving
and leap second in control functions (CF) segment.

see also table 'Assignment of CF segment in IEEE1344 mode'