SYSTEM BUS
INTERFACE:
VME bus A16:D8, slave
Access:
Short Supervisor I/O (2Dh)
Short Non-priviledged I/O (29h)
IRQ levels:
1..7, programmable
DATA FORMAT: packed BCD
PERIODIC
INTERRUPTS:
none, 10ms, 100ms, 1s, 10s, 1min, 10min, or 1h
POWER
REQUIREMENT: +5V @ 320mA
PHYSICAL
DIMENSION:
3U Euro card, 6U front panel optional
AMBIENT
TEMPERATURE: 0 ... 50°C
HUMIDITY:
max. 85 %
CE Label
This device conforms to the directive 89/336/EWG on the approxi-
mation of the laws of the Member States of the European Community
relating to electromagnetc compatibility.