Installation and setup – Metro R-Series Mobile Refrigerators User Manual
Page 4

4
INSTALLATION AND SETUP
1. Check for Shipping Damage: Check the packaging and cabinet for shipping damage before and after unloading the
unit, and after removing all packaging materials.
2. The receiver of this product is responsible for filing freight damage claims. This equipment must be opened
immediately for inspection. All visible damage must be reported to the freight company within 48 hours and must be
noted on freight bill at the time of delivery.
3. Concealed damage is your responsibility — you must advise the carrier of any loss or damage within 15 days after
receipt of the cabinet. If there is damage, retain the original packaging for inspectors.
4. After unpacking the cabinet, remove all packing material from the inside as well as outside of the unit.
5. The power cord is located at the back of the cabinet as shown in Figure 1.
6. Refer to the data plate located near the power cord for the electrical specifications of cabinet as shown in Figure 2.
◦◦ With◦the◦POWER◦switch◦OFF,◦plug◦the◦cord◦into◦the◦appropriate◦rated,◦grounded◦receptacle.
◦◦ Cabinets◦rated◦at◦120V◦must◦be◦plugged◦into◦either◦a◦15◦amp◦or◦20◦amp◦125◦VAC◦receptacle.
◦◦ Cabinets◦rated◦at◦220-240V◦must◦be◦plugged◦into◦a◦15◦amp◦250◦VAC◦receptacle.
125V
250V
15AMP
15AMP
Outlet
Outlet
When installing cabinet next to end walls, 6" (152mm) of clearance on the sides is
recommended for optimal performance.
CAUTION
: C5 R-Series cabinets (Polymer Armour panels on the sides) must not be placed next to char broilers. Allow
18" (460mm) between the Armour panels and any cooking equipment. Do not allow hot kitchen equipment
whose surfaces exceed 200°F (93°C) to touch the panels.
Slide Installation Adjustable on Uprights (Bottom Load and Lip Load)
Figure 1:
Power Cord Location on Cabinet
Figure 2:
C5 R-Series Wall Receptacles
BOTTOM LOAD
LIP LOAD
Use An Individual Branch Circuit