Seismic bolt plate kits – Metro Seismic, Floor Plates User Manual

Page 2

Advertising
background image

Seismic Bolt Plate Kits

2

Part Number:

Consists of:

6$6(6%3

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

6$6(6%3

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

6$6(6%3

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

6$6(6%3

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

6$6(6%3

 ÀRRU SODWH

(1) hardware bag

(1) label bag

6$6(6%3

 ÀRRU SODWH

(1) hardware bag

(1) label bag

SAQHD25BP-1

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

SAQHD50BP-1

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

SAQHD25BP-2

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

SAQHD50BP-2

 ÀRRU SODWHV

(1) hardware bag

(1) label bag

SAQHD25BP-4

 ÀRRU SODWH

(1) hardware bag

(1) label bag

SAQHD50BP-4

 ÀRRU SODWH

(1) hardware bag

(1) label bag

LIST OF

COMPONENTS:

(Floor Anchors not included)

INSTALLATION

INSTRUCTIONS

For Floor Mounted
Bolt Plate Kits

BOLT PLATE ASSEMBLY TO
SHELVING POST CONNECTION

The bolt plate anchor assembly is
GHVLJQHG WR DOORZ LQ¿HOG OHYHOLQJ RI
the shelving and secure anchorage of
the shelving to the bolt plates. This is
accomplished with standard shelves
and posts with leveling bolts
.

1. Place the assembled shelving unit
in its intended location.

 0DUN RQ WKH ÀRRU WKH ORFDWLRQ RI WKH
shelving posts, or place the bolt plates
under the posts. Move the shelving
unit out of the way.

3. Utilizing a template, or the actual
bolt plate, mark the location of the
ÀRRU DQFKRUV GULOO DSSURSULDWH KROHV
and install the bolt plates.

 0RYH WKH VKHOYLQJ XQLW DGMDFHQW WR
the bolt plates and level the unit. Lift
the shelving unit and place the posts
into the pipe sleeves in the bolt plate
assembly.

5. Once the shelving unit is in place
and level, horizontal holes in each
pipe sleeve are used to align a 13/32"
drill bit and a horizontal hole (or two,
as determined from the Seismic
Specifying Guide (L04-160)) is drilled
through the post. Alternatively, the
pipe sleeve holes can be used to
mark the post hole locations, the
shelving unit removed and the holes
in the post drilled.

6. Install a 3/8" diameter clevis pin (or
two) from the supplied hardware bag
through the bolt plate pipe sleeve and
post, install a hitch pin clip.

 )LQDOO\ DI¿[ WKH SURSHU ODEHO
designating the unit as either 30 psf
or 50 psf per shelf. The load rating
is determined by the tables in the
Seismic Specifying Guide and may
be shown on the installation drawing
provided with the quote package in
WKH SODQQLQJ VWDJH RI WKLV SURMHFW

Note: The lowest shelf should be as
close as possible to the bolt plate, no
KLJKHU WKDQ  IURP ÀRRU

If cleaning is an issue, it is
recommended a donut bumper
EH VSHFL¿HG WR FRYHU DQ\ VSDFHV
between the post and the bolt plate
anchor pipe. These may have been
VSHFL¿HG LQ WKH TXRWLQJ SURFHVV DQG
provided — if not, order the donut
bumper to match the post type.

Metro does not provide the concrete
ÀRRU DQFKRUV 7KH FRUUHFW ÀRRU
DQFKRUV PXVW EH XVHG IRU WKH VSHFL¿F
installation conditions and meet all
applicable codes.