Appendix C

Interface Cable Requirements

1. Customer Interface Cable Requirements

Customer cables that interface to MTE

™

series encoders must have the following characteristics:

•

Twisted pair signal wiring.

•

Characteristic impedance of 100-120 ohms.

• Sufficient wire gauge to meet the minimum voltage requirement at the encoder, for example 24AWG

gauge wire for a 2m length cable. Examples of acceptable cables with 24AWG gauge wire and 4
twisted pairs are Belden 9831, 8104, and 9844 or other manufacturer’s equivalents.

• Single shield cable with a minimum of 90% coverage. Note that a double shielded cable may be

required in high-noise applications.

MTE

Signal

Twisted Pair

A+

Pair 1

A-

B+

Pair 2

B-

Index+

Pair 3

Index-

+5V

Pair 4

GND

Fold braided shield back over jacket. Example shows double-shielded cable.
Dimensions shown are for illustration only.

Jacket

Aluminum
Polyester
Shied

Braided
Shield

3. Shield Termination:

The customer's cable shield should be in 360° contact with the connector shroud and the connector shell to
provide complete shielding. The connector shell should be metal with conductive surfaces. Suggested metal
connector shells for use with MTE

™

encoders: AMP 748676-1 or equivalent. The shield should be terminated

as illustrated in the following diagram.

2. Signal Wiring

Each differential signal should be connected to a corresponding twisted pair as follows: