INSTALLATION

Continued

INSTALLATION

Installing Damper Clamp

Damper Clamp

Damper
Clamp

Damper

Manufactured
Fireplace

Masonry Fireplace

Figure 3 - Attaching Damper Clamp

Damper

Damper

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the leading edge of the
damper as shown in Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp or permanent stop
must be installed, or the damper blade must be cut or removed.

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-

nect log set to gas supply. Follow all local codes.

Installation Items Needed

Before installing log set, make sure you have the items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve

• test gauge connection

• adjustable (crescent) wrench or pliers

• sediment trap

• tee joint

• pipe wrench

CAUTION: Use only new, black iron or steel pipe.

Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diam-
eter or greater to allow proper gas volume to log set. If
pipe is too small, undue loss of volume will occur.

We recommend that you install sediment trap in supply line as
shown in Figure 4. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into log set controls. If sediment trap is not installed or
is installed wrong, log set may not run properly.

Installation must include an equipment shutoff valve with "T" style
handle, gas union and, for propane/LP gas only, a plugged 1/8" NPT
tap. Locate NPT tap within reach for test gauge hook up. NPT tap
must be upstream from log set (see Figure 4).

IMPORTANT:

Install equipment shutoff valve in an accessible

location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in a clogged burner injector.

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

Figure 4 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 26.
** Minimum inlet pressure for purpose of input adjustment.

3" Minimum

Sediment Trap

From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

Approved Flexible Gas Hose (no longer
than 36" if required by local codes)

Tee Joint

Pipe Nipple

Cap