8 maintenance every 600 hours, Periodic inspection/maintenance – MMD Equipment 25S-3A3 User Manual

Page 53

Advertising
background image

6. Periodic Inspection/Maintenance

6-11

6.7.4 Change Filter of Fuel Air-bleeding Electromagnetic Pump (SDG45S /60S )

Turn the cap counterclockwise to remove it, change
the filter inside.

As the fuel inside spills out when it is removed,
prepare a container to catch fuel.




6.8 Maintenance Every 600 Hours

6.8.1 Change Fuel Filter (SDG75S/100S)

(Procedures)

Loosen the center bolt, remove the filter body
and element together.

After cleaning the filter body, insert a new
element into it and fasten it by the center bolt.

Bleed the air of fuel.(See 5.5)

After assembling a fuel filter, check for fuel
leakage during operation.


6.8.2 Change Filter of Fuel Air-bleeding Electromagenetic Pump

(SDG75S/100S)

Follow the same procedure for changing filter of fuel Air-bleeding electromagnetic pump as
mentioned in 6.7.4.

TR0335

SG0412

TR0335

Cap

Filter

Center bolt

Filter body

Drain plug

Part No. :
Isuzu Motors genuine
894337 0220

Part No. :
Isuzu Motors genuine
988511-1911

Advertising
This manual is related to the following products: