Installation, Chimney liner installation – Montigo DHS User Manual

Page 8

Advertising
background image

Page 8

Hotshot Gas Fireplace Insert

XG0511 - 150203

Installation

Chimney Liner Installation

This appliance is for installation with 4" diameter Type-B gas vent

(B-Vent) or double wall aluminium flex liner.

Install flex liner or B-Vent inside the masonry chimney all the

way to the top of the chimney cap. Vertical vent height must be a

minimum of 12 feet from the bottom of the fireplace to the bottom

of the termination (See Figure 4.)

Use the vent plate (supplied with the Hotshot) to connect the

chimney liner to the insert. Slide the flex over the vent plate and

attach with two sheet metal screws. Make sure the flange on the

bottom of the vent plate is toward the back of the fireplace. See

figure 5a.

Slide the Hotshot as far back as possible into the fireplace open-

ing. Reach inside the opening above the Hotshot and insert the

vent connector into the slot at the back of the fireplace. Push the

connector slide back as far as it will go to secure the chimney liner

in position. See figure 5b.

Centre the Hotshot in the fireplace opening, and connect the gas

line. (See Figure 3).

To install the face plate and louvres, see Installing Face Plate &

Trims.

All installations must conform with local codes. In the absence of local

codes, installations must conform with the most recent version of the

National Fuel Gas Code (ANSI Z223.1-1988) or the Gas Installation

Code (CAN/CGA B149.1 and .2).

10

4” Flex liner

installed to

top of chimney

Damper plate

locked in

“open” position

Vent connector

8

8

20

2 ½

Minimum 12 ft

Figure 4. Installation requirements and mantle clearances.

Figure 5a. Connecting the chimney liner to the vent plate.

Figure 5b. Securing the chimney using the connector slide.