Service, Capacitor replacement – Montigo PVHEX58-300 User Manual
Page 10
Advertising
Service
Step 1: Turn off power and gas.
Figure 5a.
Figure 5b.
Step 2: Remove 8 screws securing the outer cover of the power
head.
Figure 5c.
Step 3: Cut 3 zap straps securing wiring.
Figure 5d.
Step 4: Cut Brown Wire From Motor.
Capacitor Replacement
REC1254
Step 5: Cut white fiber wire from power cable, black wire from motor,
and black wire from capacitor.
Figure 5e.
8 fasteners (4 oposite side)
Outer Cover
Page 10
XG0517 - 070714
(4 on opposite side)
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent