General instructions – Montigo 36DRG User Manual

Page 2

Advertising
background image

Page 2 of 11

36DRG

09/96

GENERAL INSTRUCTIONS

NOTE: All gas inspection authorities in Canada require that the installation and maintenance of heaters and
accessories shall be accomplished by qualified gas fitters in accordance with the CAN/CGA B149.1 and 2
installation codes and other applicable code requirements specified by the authorities having jurisdiction.
The qualified installer shall instruct the user in the safe and correct operation of this appliance and before leav-
ing the installation, the installer shall ensure that the appliance is in safe working order. Do not remove this
booklet from installation site.

Installation must conform with local codes or, in the absence of local codes, with the current CAN1 -B149
Installation code.

A FAINT ODOUR AND SLIGHT SMOKING WILL LIKELY BE NOTICED WHEN THE FIREPLACE IS
FIRST USED. OPEN A WINDOW UNTIL THE SMOKING STOPS.

The fireplace is not intended to be used as a substitute for a furnace to heat an entire home.

Use for supplemental heating only.

The DelRay Gasfire 36DRG is rated at 28,000 BTUH for Natural Gas and 27,000 BTUH for Propane.

1./ COMBUSTION AIR

A.) In open rooms of normal construction (without
storm windows or tightly fitting doors) sufficient
combustion air can usually be supplied by infiltra
tion. Ensure that the installation location is
adequately ventilated and that the air flow supply
is not subject to obstructions.
B.) Ensure that clearance is maintained around air

opening into combustion chamber.

2./ APPLIANCE LOCATION AND

CLEARANCES

A.) Due to high temperatures, the appliance should be

located out of traffic areas and away from furni
ture and draperies ensuring a minimum clearance

of 900 mm (36 inches)
B.) Children and adults should be alerted to the

hazards of high surface temperature and should
stay away to avoid burns or clothing ignition.

C.) Young children should be carefully supervised.

when they are in the same room as the fireplace.

D.) Clothing or other flammable material should NOT

be placed on or near the fireplace.

E.) Minimum side clearances to combustibles:
Side Facing: 1"Perpendicular Wall: 3"
Top Facing: 8" Mantle: 18 1/2" {based
(See Drawing #1)

on 10" shelf depth}

F.) The appliance must be installed in a vented solid
fuel fireplace with a working flue and constructed of a
noncombustible material. (Not for use with air tight
units).

8"

2 1/2"

8"

26 3/8"

DRAWING #1

10"

Damper
plate
locked in
"Open"
position

Advertising