DeVillbiss Air Power Company D23757 User Manual

Page 19

Advertising
background image

19- ENG

D23757

PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Check fuse box for blown
fuse and replace as neces-
sary.

Reset circuit break-

er. Do not use a fuse or cir-
cuit breaker with higher rat-
ing than that specified for
your particular branch circuit.

Check for proper fuse. You
should use a time delay fuse.

Check for low voltage prob-
lem.

Check the extension cord.

Disconnect the other electri-
cal appliances from circuit or
operate the compressor on
its own branch circuit.

Have checked by a Trained
Service Technician.

Fuse blown, circuit breaker
tripped.

Extension cord is wrong
length or gauge.

Loose electrical connec-
tions.

Faulty motor.

Check the extension cord.

Check wiring connection
inside terminal box.