Desa Models 5312 User Manual

Motion sensor light control with 2-level lighting, Operation

Advertising
background image

Models 5312 & 5318

Motion Sensor Light
Control with 2-Level
Lighting

© 2007 DESA Specialty Products™

598-1274-00

TEST

2 Shells*

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• 2-Level Lighting Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to
Dawn

2-Level Lighting

Put ON-TIME switch on
the sensor bottom to
TEST and the 2-Level
Lighting switch OFF.

2-LEVEL LIGHTING TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5,
or 20 minutes) then returns to dim mode.

* Model SL-5318 only

®

Mode: On-Time:

Works:

Day

Night

Test 5

Sec

x

x

Auto

1, 5, 20 min.

x

Manual Until

Dawn*

x

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

TEST 1 5 20

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Note: When fi rst turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

This package includes:

Light Control

Sensor

Cover

Plate

Lamp

Holders

Plastic Hanger

Rubber Plug

Gasket

6 Screws

(3 sizes included)

Mounting Strap

Mounting Bolt

2 Wire

Connectors

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

S o m e c o d e s r e q u i r e i n s t a l l a t i o n by a

qualifi ed electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Advertising