6.

Ideally the large kindling should be burned until a thick bed of red embers is obtained. At that
point, add cordwood fuel and continue to operate the draft control wide open until the fire is well
established. Once the firebox is hot, the draft control can be partially closed by moving the knob to
the left to adjust the intensity of the fire.

Use Table 3.2 to adjust the draft control to the desired burn rate:

Draft Settings

Burn Rate

Draft Setting

Low

Push Control to end of travel.

Medium Low

Pull Control by 3/8” from closed position.

Medium High

Pull Control by 3/4” from closed position

High

Pull Control to end of travel.

Table 3.2


Closing the draft control down too soon will lower combustion efficiency, and may result in creosote
build-up in the chimney (which could lead to a chimney fire).

C

AUTION

:

T

HE

A

DJUSTMENT

R

ANGE

S

HOULD

N

OT

B

E

A

LTERED

F

OR

I

NCREASED

F

IRING

F

OR

A

NY

R

EASON

.

CLOSED

OPENED

DAMPER OPERATION

Figure 3.1