3 Configuration

The ADP-3GHD supports a number of different formats. The correct configuration can either
be set with a DIP switch or with the GYDA system controller. The layout of ADP-3GHD is
shown in the drawing below.

Figure 2 - ADP-3GHD module layout

DIP switch configuration must be set according to the table below:

Switch
#

Label Function DIP=OFF

Function DIP=ON

Comment

1

RED

Independent rings

Redundant ring

Card can work on
either two independent
rings or one ring with
redundant
paths/directions.
Redundant mode
implies CHO function
on DROP outputs.

2

R1

Pass primary ring

Add to primary ring

Chooses which signal
goes to the OUT port of
the primary ring

3

R1

Drop from primary ring

No drop from primary
ring

Enable DROP output
for the primary ring.

4

R2

Pass secondary ring

Add to secondary ring Only in use when

switch #1 set OFF

5

R2

Drop from secondary ring No drop from

secondary ring

Only in use when
switch #1 set OFF

6

RCL

Reclocker Bypass

Reclocker ON

Reclocker mode

7

EQ

Cable equalizer Bypass

(Loss of signal will not
work on this mode)

Cable Equalizer ON

Equalizer mode

8

OVR

Module controlled by
Gyda system controller

Module controlled by
DIP switches

Select GYDA config.
Mode

Table 1: ADP-3GHD DIP switches

All DIP switches are off when pointing towards the release handle.