Model 3vg79b, Maintenance (continued) – Dayton 3VG79B User Manual

Page 7

Advertising
background image

Dayton Operating Instructions and Parts Manual

7

Model 3VG79B

Version B - For Reduction

G016.J

®

Maintenance (Continued)

Side
Cover

Bushing, Lower Fuel Line,
and Fuel Filter

Figure 10 - Fuel Filter Removal

Fuel Valve
Fitting

4. Disconnect red and white wires from

fuel valve (See Figure 11).

5. Using 1/4" nut driver remove 2 screws/

lockwashers holding fuel valve and
bracket to lower shell (See Figure 11).
Save these screws/lock washers.

6. Using 1/4" nut driver remove 2 screws

holding fuel valve to bracket. Save these
screws.

7. Attach new fuel valve to bracket with 2

screws.

8. Install new fuel valve and bracket on

lower shell with 2 screws/lockwashers.

9. Connect red and white wires (polarity

not important). Connect upper and
lower fuel lines to fuel valve.

10. Replace fan, fan guard, upper shell, and

side cover.

Lower Fuel
Line

Electrical
Wires

Fuel Valve

Valve
Fittings

Bracket

Screw

Screw

Figure 11 - Fuel Valve Replacement

Lock Washer

IGNITOR

1. Remove upper shell and fan guard

(See Figure 5, page 5).

2. Remove fan (See pages 5 and 6).

3. Remove 4 side cover screws with a

5/16" nut driver. Remove side cover
(See Figure 10).

4. Disconnect ignitor wires (black) from

ignition control assembly (See Figure
12). Pull the ignitor wires up through
the hole in the lower shell.

5. Disconnect fuel line hose and air line

hose. Remove photocell from photo-
cell bracket (See Figure 12).

6. Remove combustion chamber. Stand

combustion chamber on end with
nozzle adapter bracket on top (See
Figure 13, page 8).

7. Remove ignitor screw with a 1/4" nut

driver. Carefully remove ignitor from
nozzle adapter bracket.

Do not bend or
strike ignitor

element. Handle with care.

8. Carefully remove replacement ignitor

from styrofoam packing.

9. Carefully guide ignitor into opening in

nozzle adapter bracket. Do not strike
ignitor element. Attach ignitor to nozzle
adapter bracket with screw using a 1/4"
nut driver (See Figure 13, page 8).
Torque 8 to 15 in. lbs. Do not over
torque.

10. Replace combustion chamber.

11. Route the ignitor wires back down

through the hole in the lower shell.
Connect wires to the ignition control
assembly.

12. Replace side cover (See Figure 10).

13. Connect and route fuel line hose and

air line hose to nozzle assembly (See
Figure 14, page 8).

14. Replace photocell in photocell bracket.

15. Replace fan (See pages 5 and 6).

16. Replace fan guard and upper shell

(See pages 5 and 6).

Figure 12 - Disconnecting Ignitor Wires
from Ignition Control Assembly

Combustion
Chamber

Photocell
Bracket

Photocell
Assembly

Air
Line
Hose

Fuel
Line
Hose

Ignitor
Wires

Ignitor

Nozzle
Adapter
Bracket

Ignition
Control
Assembly

Side Cover

Advertising