Northern Airborne Technology 250 User Manual

Page 23

Advertising
background image

EQUIPMENT MANUAL 250-16-1

250/250-16-1

Page 14


Table 2. Environmental Qualification Form

NOMENCLATURE: Passenger Speaker Amplifier

TYPE/MODEL/PART NO.: Model 250-[ ] TSO NUMBER: TSO-C50c

MANUFACTURER'S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATION: dB Systems
Document

No.

250-16-1,

Equipment

Manual

MANUFACTURER:

dB

Systems,

Inc.

ADDRESS: 2847 152nd Ave. N.E., Redmond, WA 98052


Conditions

DO-160C
Section/
Paragraph


Description of Conducted Tests

Temperature and altitude

Low temperature
High temperature


In-flight loss of cooling

Altitude

Decompression


Overpressure

4.0

4.5.1
4.5.2
4.5.3

4.5.4

4.6.1

4.6.2


4.6.3

Equipment tested to Category F2.

(see also temperature variation)
(see also temperature variation)
(see also temperature variation)

Equipment does not require special cooling.

Equipment tested at +70,000 feet.

Equipment tested to Category A2, except
decompressed to +55,000 feet.

Equipment tested to Category A2.

Temperature variation

5.0

Equipment tested to Category B; combined
with 4.5.1, 4.5.2, & 4.5.3.

Humidity

6.0

Equipment tested to category A requirements.

Operational shocks and
Crash safety

Operational shocks
Crash safety

7.0


7.2
7.3


Equipment tested without shock mounts per
DO-160C, paragraphs 7.2.1, 7.3.1, 7.3.2, &
7.3.2.2.

Vibration

8.0

Equipment tested without shock mounts to
Category L, except extended curve 150-2,000
Hz 3g pk. Equipment tested without shock
mounts to Category C. No change in critical
frequencies during tests.

Explosion proofness

9.0

Equipment identified as Category X, no test
required.

Waterproofness

10.0

Equipment identified as Category X, no test
required.

Fluids susceptibility

11.0

Equipment identified as Category X, no test
required.

Advertising