Olson Technology LegacyPlus User Manual

Page 5

Advertising
background image

025-000480 REV X1

Page 5

OPTICAL CONNECTORS AND CLEANING

The standard optical connector provided with the AM-MB-RPTDB/SC/302/1 is an SC/APC with an 8° angle. No tools are required for
connection to/from this type of optical connector.

The fiber ends can be damaged by the insertion of contaminated connectors into a bulkhead or receptacle, or by the insertion of a
clean connector into a dirty bulkhead. Fiber connectors should never be left uncovered. Optical connectors should be cleaned
before usage. Prepackaged alcohol wipes are the most convenient way to insure clean optical connectors. Fresh, clean alcohol and

lint free wipes or swabs may also be used.

EXTERNAL TEST POINTS

The AM-MB-RPTDB/SC/302/1 has 1 external test point for optical power output calibrated at 10V/mW. It should be monitored with
a high impedance voltmeter. This test point is for long term monitoring purposes. The optical output power should be measured
using an optical power meter at the time of installation.

Advertising
This manual is related to the following products: