Olson Technology LCM-500-550-DF User Manual
Page 2
Advertising

025-000417 REV B
Page 2
LCM-500-550-DF ADDENDUM
The LCM-500-550-DF has a digital TV SAW filter in place of the normal VSB
SAW filter. To use as a I.F. to R.F. up converter, remove the I.F. jumper
between the “IF OUT” and “IF IN” connectors on the rear panel.
Connect the I.F. signal source to the “IF IN” connector. The level should
be +35 dBmV with a center frequency of 44.0 MHz.
Set the front panel DIP switches to the desired output frequency.
Description
I.F. Input
Center Frequency
44.0MHz
Level
+35dBmV
Impedance
75 Ohms
I.F. to R.F. Response
Gain
20dB Minimum
1 dB Bandwidth
5.0MHz Typical
3 dB Bandwidth
6.0MHz Typical
Group Delay
+/- 40 nS Typical
Additional Specifications