Lp-dc234 – Olson Technology LP-DC-X User Manual
Page 9
Advertising

025-370447 REV X2
Page 9 of 10
FRONT PANEL
There are 2 front panel –20dB RF test points. For level setting, the accuracy of
these band 2 and band 4 test points is ± 1dB. No 4.5 MHz pilot is present at these test
points.
The power LED should always be on and green. The alarm LED is always on.
It is green unless a failure occurs. It monitors VCXO unlock.
REAR PANEL
The rear panel has the 2 RF F output connectors and the 2 SMB connectors that
connect to the LP-DC212.
FUSE
The module has an internal miniature 3A SB fuse in a holder. The Littelfuse part
number is 0454003. The Olson Technology P/N is 286-000009.
LP-DC234
ALARM
POWER ON
BAND 2
T.P.
LP-DC-234
BAND 4
T.P.
Advertising