Olson Technology OTOHP-RRX User Manual

Page 6

Advertising
background image

UNINSTALL THE RECEIVER MODULES

ALARM DEFINITIONS

DANGER: Laser Radiation—Avoid direct exposure to beam. Inbound laser radiation
associated with this optical input jumper may be generated by a Class IIIb laser product.
Disconnected optical connectors might emit invisible optical radiation. Laser light, visible
or invisible, can seriously injure eyes and even cause blindness.

1

Disconnect the optical fiber s from the rear panel of the receiver. Immediately
place protective caps over the bulkhead and fiber connector

2

Disconnect the RF cables from the F connectors

3. Loosen the thumbscrew on the front panel of the module CAUTION: Do not pull

on the thumbscrew to remove the module. Pull on the handle that the thumbscrew
goes through to remove the module.

4. Gently pull the module from the chassis using the handle that the thumbscrew

goes through

First push SET into LED display and set function.

.

( )

.

.

-

.

.

.

Displayed Message

Alarm Status

System Response

No alarm

STA LED is green

Optical input low for Port 1

STA LED turns to red

Optical input high for Port 1

000
001
002
003
004
005

STA LED turns to red
STA LED turns to red
STA LED turns to red
STA LED turns to red

Optical input low for Port 2

Optical input high for Port 2

006

STA LED turns to red

007

STA LED turns to red

008

STA LED turns to red

009

Module temperature high

STA LED turns to red

Optical input low for Port 3

Optical input high for Port 3

Optical input low for Port 4

Optical input high for Port 4

Advertising