Loop Detector Wiring

Loops and loop detectors must be installed with this gate operator to prevent the gate from
accidentally closing on vehicles that may be in the path of the gate
.

Detail A

Detail A

TB 1

From inside

Reverse loop

From outside
Reverse loop

Reverse

Reverse

Exit

DOORKING, INC., INGLEWOOD, CA 90301

Title:

Date:

Rev.

Dwg. No.

DoorKing

Loop Detector

DoorKing

Loop Detector

8 Loops and loop detectors MUST be installed with this gate

operator to help prevent the gate from accidentally closing on
vehicular traffic.

8 Loop detector wiring is shown for DoorKing plug-in loop

detectors only. If other loop detectors are used, refer to the
installation instructions supplied with those detectors for
wiring instructions.

8 If other detectors are used, use a separate power supply to

power these detectors.

8 Loop layout shown is for a typical slide gate application with

two-way traffic, or one-way exit only traffic.

8 Reverse loops are wired in series. See detail A.
8 Refer to the Loop Information Manual (available from

www.dkaccess.com) for more information on loops and loop
detectors.

11/07

A

4404-LOOP-1

Model 9210, 9220, 9230, 9530
Loop Detector Wiring

1

11

10

9

8

7

6

5

4

3

2

20

19

18

17

16

15

14

13

12

TIME

DELAY

REV SENS

OPEN

REV SENS

CLOSE

REVERSE
LOOP

R

E

L

A

Y

CO

NT
A

CT

REVERSING DEVICE

CONNECTOR

P5

ON

4 3 2 1

8 7 6 5 4 3 2 1

EXIT

LOOP

LIMIT SWITCH

CONNECTOR

LMT

POWER

P6

P2

P7

P8