Slide gate requirements, Ab b – DoorKing 9220 User Manual

Page 10

Advertising
background image

Slide Gate Requirements

Ga

te

Roadway

Pedestrian

Access

Fence

Vehicular Gate

Sidewalk

Operator

Fence

All openings of a horizontal slide gate are guarded or screened from the
bottom of the gate to a minimum of four (4) feet (1.22 m) above the ground to
prevent a 2 1/4 inch (57.2 mm) diameter sphere from passing through the
openings anywhere in the gate and in that portion of the adjacent fence that
the gate covers in the open position.
(ref. UL325 56.8.4.a.2 and ASTM F2200 6.1.2)

The operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a seperate access opening. The
pedestrian access opening shall be designed to promote pedestrian
usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
(ref. UL325 56.8.4.b)

Fence

4 ft.
min

Gate

A gap, measured in the horizontal plane parallel to
the roadway, between a fixed stationary object
nearest the roadway (such as a gate support post)
and the gate frame when the gate is in either the
fully open position or the fully closed position, shall
not exceed 2 1/4 inch (57.2 mm).
(ref. ASTM F2200 6.1.4)

2 1/4"

Max

2 1/4"

Max

Operator

Pad

Fe

nce

A

A

E

n

tra

p

m

ent

A

rea

A

B

B

This area between the gate and fence has a high risk of entrapment. The gap between the fence and gate should not exceed
2 ¼ inches. Install a filler or barrier in this area to reduce this gap to 2 ¼ inches or less.

Install a contact sensor (type B2) on the fence to help minimize the risk of entrapment in this area.