background image

6. Filter bypass master switch

In case you desire to deactivate or to control unit filters operation, it’s
possible to simultaneously deactivate all the filters pressing the switch
(fig.1 ref.3) to its OUT position. To make filters active again press again
the switch, IN.

Operations

a. To turn on the unit press the POWER switch ON, its led is lit.
b. To turn off the unit press the POWER switch OFF, its led too will be off

as well.

c. In order to do an accurate frequency setting, please use the unit front

panel frequency/level LED indicator.

d. To activate/de-activate all NOTCH filters use the IN/OUT switch (fig.1

ref.3).

e. In order to modify attenuation frequency, please use FREQ knob and

x1 x10 switch, the choose the attenuation use DEPTH knob (fig.1 ref.4).

Warning: In order to avoid forthcoming units damage, please before

connecting any sound source to this unit, control that its volume is totally
lowered.

Technical Specifications

Model

AF4

Input connector

Balanced 6.3mm (1/4”) jack

Output connector

Balanced 6.3mm (1/4”) jack

Frequency response

20Hz~20KHz > -1dB

Signal/noise ratio

< 68dB

Input sensitivity/impedance 0.775V

(0dBm)/15KΩ

Output level/impedance

0.775V (0dBm)/600Ω

NOTCH filters frequency range

60Hz~6KHz

Filter attenuation

0 ~ -20dB

Power consumption

5.5 W

Power requirements

AC 110~120 / 220~230V – 50/60Hz

DC 24V

Rack dimension

1U 19” standard

Dimensions WxHxD

483x44x210 (mm.) – 19in. x 1.75in. x 8.2in.

Weight

3 Kg – 6.8lbs

Advertising