Profax WATER-SOLUBLE PURGE DAMS User Manual
Page 2
 
1. For small diameter pipes 
(less than 4” inner 
diameter), simply position 
a wad of Tig Master paper 
several inches down into 
each section to be joined.
2. For larger pipes (4” inner 
diameter and larger), cut 
the paper into a circle with 
a diameter several inches 
larger than the pipe ID. 
Example: for a 6” pipe, cut 
and 8” diameter paper 
circle.
3. Trace or impress the 
pipe and inner diameter on 
the paper and fold on this 
line to form a 90 degree 
lip. Insert the dam into the 
pipe and with the lip 
towards the weld prep.
4. Peel the tape from the 
backing and tape dam in 
place. Optional: Punch a 
small hole in the dam to 
facilitate the evacuation of 
air when purging.
5. For pipes larger than 28” 
diameter, simply splice two 
or more sheets of Tig 
Master paper together with 
Tig Master tape, and 
proceed as in steps 2, 3, 
and 4.
6. After the dams are in 
place, Argon may be 
introduced through the root 
gap with needle valve 
connected to the line.
7. If one end of the pipe is accessible, the purge gas may be 
introduced through a hole at the lower end of one dam. A vent 
hole should be made at the upper end of the other dam to allow 
air and gases to escape. Optional: cover the open root joint on 
the outside of the pipe with tape to prevent gas leakage.