Optional positioning of thermostat sensing bulb – Desa CDL3924PT User Manual

Page 25

Advertising
background image

www.desatech.com

111347-01E

25

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

For Masonry and Factory-Built Metal
Fireplace

If your log set cycles to pilot, but the room tem-

perature drops to a lower than ideal comfort level

before the log set comes back on, you may want

to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the

gas valve assembly on the mounting bracket. This

location allows the thermostat to keep the room

temperature at an ideal comfort level for most

fireplace applications. For positioning the thermo-

stat sensing bulb elsewhere, an adhesive-backed

mounting clip is available (see Figure 31).
Tools needed: 1/4" hex driver or socket
1. Remove logs. Locate the gas valve assembly

and thermostat sensing bulb (see Figure 32).

2. With 1/4" hex driver or socket, loosen the

thermostat screw. Carefully slide the thermostat

sensing bulb out of the retaining clamp (see

Figure 33).

Note:

Do not remove the screw. Make sure

you tighten the screw after removing the

thermostat sensing bulb.

IMPORTANT:

Do not force or bend the

thermostat sensing bulb or capillary.

3. The thermostat sensing bulb may be located to

the lower right front side of fireplace. Determine

location of sensing bulb, but do not mount

sensing bulb until step 5. If you have a masonry

fireplace, see Figure 34 for location. If you have

a factory-built metal fireplace, see Figure 35

for location. If your fireplace has glass doors,

position sensing bulb directly behind door gap

on right bottom side (see Figure 36).

Thermostat
Sensing Bulb

Figure 32 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Gas Valve
Assembly

Figure 31- Adhesive-backed Mounting

Clip

Figure 33 - Removing Thermostat

Sensing Bulb

Thermostat
Screw

Retaining
Clamp

Thermostat
Sensing Bulb

Capillary

Adhesive-

Backed

Mounting Clip

Figure 34 - Locating

Thermostat

Sensing Bulb on

Masonry Fireplace

Thermostat

Sensing

Bulb

Figure 35 - Locating

Thermostat Sensing

Bulb on Factory-

built Metal Fireplace

Adhesive-
backed
Mounting
Clip

Glass
Doors

Thermostat
Sensing Bulb

Figure 36 - Installing Thermostat Sensing

Bulb behind Glass Doors