Product identification, Product features, Air for combustion and ventilation – Desa CDL3924PT User Manual

Page 5

Advertising
background image

www.desatech.com

111347-01E

5

Figure 1 - Product Identification

Meadowbrook Oak Logs with Thermostat

Control

Echo Valley Oak Logs with Manual

Control

Control
Knob

Control
Cover Log

Control
Cover Log

Piezo Ignitor
(behind log)

Piezo Ignitor
(behind log)

Control
Knob

PRODUCT

IDENTIFICATION

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re-

quires no matches, batteries or other sources to

light heater.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall not

be installed in a confined space

or unusually tight construction

unless provisions are provided

for adequate combustion and

ventilation air. Read the following

instructions to insure proper fresh

air for this and other fuel-burning

appliances in your home.

Todayʼs homes are built more energy efficient

than ever. New materials, increased insulation and

new construction methods help reduce heat loss

in homes. Home owners weather strip and caulk

around windows and doors to keep the cold air out

and the warm air in. During heating months, home

owners want their homes as airtight as possible.
While it is good to make your home energy effi-

cient, your home needs to breathe. Fresh air must

enter your home. All fuel-burning appliances need

fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel

burning appliances draw air from the house to

operate. You must provide adequate fresh air for

these appliances. This will insure proper venting

of vented fuel-burning appliances.

PROVIDING ADEQUATE
VENTILATION

The following are excerpts from National Fuel

Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,

Air for Combustion and Ventilation

.

All spaces in homes fall into one of the three fol-

lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help

you classify your space and provide adequate

ventilation.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside

venting. There is no heat loss out a vent or up a

chimney. Heat is generated by realistic flames. This

heater is designed for vent-free operation with flue

damper closed. It has been tested and approved

to ANSI Z21.11.2 standard for unvented heaters.

State and local codes in some areas prohibit the

use of vent-free heaters. This heater may also be

operated as a vented decorative (ANSI Z21.60)

product by opening the flue damper.

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS/pilot is a required feature for vent-free room

heaters. The ODS/pilot shuts off the heater if there

is not enough fresh air.