Wiring diagram, Terminal strip dkw 976 – REMKO SLV11-88-2 User Manual
Page 10

10
Wiring Diagram
Control relay DKW 976 for the model sizes SLV 11 to SL 44
L1
N
T1
T2
S3
B4
Control line to
warm air generator
L1
N
T1
T2
S3
B4
7-pin connector
in accordance
with DIN 4791
Caution !
4-pin plug is only used
internally and has to be
plugged in during
operation
B5
T6
T7
T8
B5
T6
T7
T8
MV2 MV1
ZT
FW
M
Terminal strip DKW 972
Terminal strip Conectron LKS 130-2 adjustment motor
6 A
8
4 1 2 3 8 5 7 9
8
4 8
7
3
1 2
Control relay DKW 972 model sizes SL 55/2 and SL 66/2
L1 N
T1
T2
S3
B4
Terminal strip DKW 976
FW
N
C1
WS
Z M
MV1
MV2 SA
ÖV
FT
1 2
3 4 5 6 7 8 9
B
1)
1)
1) Note: Burner of the SL 44 model size without nozzle connection rod preheater. Preinstalled bridge from terminal 4 to 6.