Technical data – REMKO CLK 20 User Manual

Page 12

Advertising
background image

12

Technical Data

Model

CLK 20

Max. nominal heat load

kW

22

Nominal heat output

kW

20

Nominal air volume flow

m³/h

1.860

Pressure (max. total)

Pa

95

Fuel

EL heating oil or diesel according to DIN 51603 or
diesel fuel

Max. fuel consumption

L/h

2.20

Oil nozzle (Danfoss)

2)

USG

0.5/60°S

Pump pressure, approx.

2)

bar

10.5 – 11.0

Max. chimney loss

%

9

Chimney volume, approx.

kg/h

35

Furnace resistance, approx. (start/operation)

Pa

140/40

Required chimney draft

Pa

0

Electrical connection

V/Hz

1~ 230/50

Max. power consumption (ges. Gerät)

W

320

Max. nominal current

(ges. Gerät)

A

1.45

Max. power consumption (Ventilator)

W

130

Max. nominal current

(Ventilator)

A

0.6

Operating capacitor of the fan

µF

3

Fuse protection (on site)

A

10

Temperature increase (

t

)

K

41

Sound pressure level L

pA

1m

3)

dB (A)

60

Air outlet ø

mm

300

Chimney adapter Ø

mm

130

Total unit length

mm

1.180

Total unit width/with wheel attachment

mm

510/580

Total unit height/with wheel attachment

mm

735/880

Weight with forced-air oil burner

kg

94

2) The listed nozzle sizes and pump pressures were determined on the basis of adjustment tests on a test stand. The oil throughput was meas-
ured out.

(The specifications serve only as standard values due to product-specific nozzle and pressure tolerances and oil temperatures.)

3) Noise measurement according to DIN 45635 - 01 – Cl. 3 (without burner operation)

We reserve the right to make changes in dimensions and design in the interest of technical advances.

Advertising