CAUTION: This fireplace cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to fireplace. Installing

fireplace next to vinyl or cloth

wall coverings or operating

fireplace where impurities (such

as, but not limited to, tobacco

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps,

etc.) in the air exist, may discolor

walls or cause odors.

IMPORTANT:

Vent-free fireplaces add moisture

to the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may

cause mildew to form from too much moisture. See

Air for Combustion and Ventilation, page 6.
Note:

When installing fireplace directly on carpet-

ing, tile or other combustible material, other than

wood flooring, the fireplace shall be installed on a

metal or wood panel extending the full width and

depth of the fireplace.

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18 inches above

floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fireplace
• where there is easy access for operation, inspec-

tion and service.

• in coldest part of room
An optional blower kit is available from your

dealer. See Accessories, page 27. If planning to use

blower, locate fireplace near an electrical outlet.

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves

installing fireplace into a framed-in enclosure.

This makes the front of fireplace flush with wall.

An optional brass trim kit accessory is available

(see Accessories, page 27). Brass trim will extend

past sides of fireplace approximately 1/2 inch. This

will cover the rough edges of the wall opening. If

installing a built-in mantel above the fireplace, you

must follow the clearances shown in Figure 12,

page 12. Follow the instructions below to install

the fireplace in this manner. Note: Your fireplace is

designed to be used in zero clearance installations.

Wall or framing material can be placed directly

against any exterior surface on the rear, sides or

top of your fireplace.

Actual Framing

Height

26"

26

7

/

8

"

Front Width

26

3

/

4

" 26

7

/

8

"

Depth

9

1

/

2

"

10

1

/

2

"

Bottom

3/4"

3/4"

1. Frame in rough opening. Use dimensions

shown in Figure 8 for the rough opening.

If installing in a corner, use dimensions shown

in Figure 9 for the rough opening. The height

is 26

7

/

8

" which is the same as the wall opening

above.

36

5

/

8

"

25

7

/

8

"

51

3

/

4

"

26

7

/

8

"

26

7

/

8

"

26

7

/

8

"

3/4" Off
The Floor
Minimum

10

1

/

2

"

Figure 8 - Rough Opening for Installing

in Wall

Figure 9 - Rough Opening for Installing

in Corner

INSTALLATION