Directed Audio XTR5002 User Manual

Page 19

Advertising
background image

© 2008 Directed Electronics. All rights reserved.

18

Symptom

Probable Cause

Action To Take

speaker not connected to amplifier properly .

Check speaker wires and repair or replace as needed . Refer to the Speaker
Connections
section of this manual for detailed instructions

Internal crossover not set properly for speakers

Readjust crossovers . Refer to the Internal Crossover Configuration section of
this manual for detailed instructions .

speakers are blown

Check system with known working speakers and fix or replace as needed .

Poor bass response

speakers wired with wrong polarity causing can-
cellation at low frequencies .

Check speaker polarity and fix as needed .

Crossover set incorrectly

Reset crossovers . Refer to the Internal Crossover Configuration section of
this manual for detailed instructions .

Impedance load at amplifier is too low .

Check speaker impedance load if below 2

Ω, rewire speakers to achieve

higher impedance .

Battery fuse blowing

short in power wire or incorrect wiring .

Check power wires and ground connections and repair or replace as needed .

Fuse used is smaller than recommended .

Replace with proper fuse size .

Actual current exceeds fuse rating .

Check speaker impedance load if below 2

Ω, rewire speakers to achieve

higher impedance .

speaker is blown with shorted outputs

Check system with known working speakers and fix or replace as needed .

Advertising