Storage, Maintenance, Specifications – Desa Td101a User Manual

Page 7

Advertising
background image

www.desatech.com

7

1749-01A

SPECIFICATIONS

• Rating: High - 16,000 Btu/Hr (4.69 kw)

Low - 9,500 Btu/Hr (.78 kw)

• Fuel: Propane Vapor Only
• Fuel Consumption/Hour: Min. 0.10 gal (0.39 liter), Max. 0.17 gal (0.66 liter)
Min. 0.44 lb (0.0 kg), Max 0.74 lb (0.33 kg)
• Supply Pressure (To Regulator): Maximum - 00 psi (1,379 Kpa)
Minimum, for input adjustment - 5 psi (34.5 Kpa)
• Manifold Pressure: High - 11 WC (.74 kPa), Low - 10.6 psi (73.08 kPa)
• Ignitor Gap: 0.10"
• Minimum Temperature: -0°F (-9°C) Surrounding Air Temperature
• Heater Size (L x W x H): 30.5" x 30.5" x 43.5" (0.77 x 0.77 x 1.1 m)
• Carton Size (L x W x H): 5.75" x 5.75" x 16.5" (0.65 x 0.65 x 0.41 m)
• Heater Weight: 58 lb (6.3 kg)
• Shipping Weight: 68 lb (30.8 kg)

STORAgE

WARNING: Never attempt to

service heater while it is con-

nected to propane/LP supply,

operating, or hot. Severe burns

can occur. Any guard or other

protective device removed for

servicing must be replaced prior

to operating the heater.

1. Keep heater clean. Remove any debris

from ventilation openings.

. Inspect heater before each use. Check

connections for leaks. Apply mixture of

CAUTION: Disconnect heater

from propane/LP supply cylinder.

1. Do not store heater while attached to

propane/LP cylinder. Close cylinder valve.
Remove the hose/regulator assembly
from the propane/LP cylinder by turning
the fuel gas connector nut clockwise.

. Storage of heater inside is permissible

only if the cylinder is disconnected and
removed from the appliance.

3. Store propane/LP cylinder in safe manner.

Refer to Chapter 5 of Standard for Storage
and Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58.
Follow all local codes.
Cylinders must be stored outdoors in a
well-ventilated area out of reach of children.
Disconnected cylinders must have threaded
valve plugs tightly installed, and must not be
stored in a building, garage or any other en-
closed area. Never store cylinders near high
heat, open flame, or where temperatures
exceed 100° F (38° C).

4. Store in a dry, clean, and safe place.

MAINTENANCE

liquid soap and water to connections.
Bubbles forming show a leak that must
be corrected. Correct all leaks at once.

3. Inspect hose/regulator assembly before

each use. If hose is highly worn or cut,
replace it immediately. At least annually,
remove hose/regulator assembly from
heater to inspect entire length of hose.

4. Spiders and insects can create a danger-

ous condition that may damage heater or
make it unsafe. Keep burner area clean
of all spiders, webs, or insects.

5. Have heater inspected yearly by a quali-

fied service person.

Advertising
This manual is related to the following products: