Minimum chimney height, Maximum chimney height, Chimney maintenance – Desa VPN36 3-SIDED User Manual

Page 10: Roof opening chart

Advertising
background image

10

55505

Figure 23

VRTL-10D

VSC-10

FLASHING

VFS-10DM

VFS-10DM

V30FS-10DM

V30E-10DM

MINIMUM

HEIGHT

15 FT.

MAXIMUM

HEIGHT

CHASE

TERMINATION

50 FT.

VRTL-10D

VETL-10D

MINIMUM CHIMNEY HEIGHT

The minimum chimney height (measured from bottom of firebox to
flue gas outlet-end of pipe) is 15 feet for a straight run, 16 feet min.
for a run with 1 elbow set (a set consists of one starter elbow and one
return elbow).

Uncommon circumstances such as neighboring hills, tall trees, or
strong wind areas can cause downdrafts in the chimney system. In
such cases going beyond the minimum recommended height would
be preferable to provide a better draw.

MAXIMUM CHIMNEY HEIGHT

The maximum height approved for any chimney run with this
firebox system is 50 feet measured from bottom of firebox to flue
outlet-end of pipe.

CHIMNEY MAINTENANCE

Have your chimney system cleaned and inspected regularly to
ensure safe and efficient operation. Refer to your Owner's
Manual for further guidelines on maintenance and operation.

Using Figure 24 and the chart below, determine the opening that will
be required for the pitch of your particular roof.

Figure 24

19" MIN.

(482.6mm)

2" MIN.

(50.8mm)

2" MIN.

(50.8mm)

2" MIN.

(50.8mm)

30" MIN.

(762mm)

OPENING

"A"

ROOF OPENING CHART

PITCH

OPENING "A" USE FLASHING NO.

FLAT

19

V6F10

6/12

23

1

/

4

V6F10

(26.6 DEG. SLOPE)

12/12

30

3

/

4

V12F10

(45 DEG. SLOPE)

Before cutting hole, temporarily remove shingles around area to be
opened. After preparing the opening on the roof, continue to add
sections of pipe until it extends a minimum of 30 inches above
highest point of roof cutout (see Figure 24).

With the termination the minimum height should add up 3 feet (see
10-Foot Rule and Figure 22).

Advertising