Operational characteristics: cme2006r, Cme2006r – Scotsman CME2006R User Manual

Page 35

Advertising
background image

Operational Characteristics: CME2006R

Cycle Times (minutes):

System Pressures (PSIG):

70

o

F. condenser air 70

o

F. indoor

air, 50

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Freeze 11 - 13 13 - 14

Harvest 2 ½ 2

70

o

F. condenser air 70

o

F. indoor

air, 55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Suction: End of Freeze 23 - 26 25 - 27

Suction: Peak in Harvest 80 - 90 90 - 100

Discharge: 5 minutes into Freeze 240 - 250 250 - 270

Discharge: Minimum in Harvest 145 160

0

2

4

6

8

10

12

14

Beg 2

mins

3

mins

5

mins

1st

fill

10

mins

End Hvst End

Hvst

Three Phase Amp Draw

Freeze Cycle

Harvest

Number of Evaporators:

•

6

Refrigerant Charge

•

336 ounces of R-404A

Compressor Type

•

Three Phase: Copeland Scroll ZS30K4E-TF5-230

•

Single Phase: Copeland Scroll ZS30K4E-PFV-230

Typical Compressor Amps,

single phase

•

freeze 19.6

•

harvest 22.5

three phase

•

11 to 9 freeze

•

11 harvest

Typical Harvest Ice Weight

•

20 - 21 lb.

Hi Pressure Cut Out - Automatic Reset

•

Hi Pressure Cut Out - 450 PSIG

•

Hi Pressure Cut In - 350 PSIG

Low Pressure Cut Out - Automatic Reset

•

Cut Out at 15 PSIG

•

Cut In at 30 PSIG

Headmaster Valve

•

Setting is 217 PSIG

CME2006R

July 1998

Page 35