Sccg50 & sccp50 service manual – Scotsman SCCG50 User Manual

Page 31

Advertising
background image

Removal and Repair - Cabinet Removal

Certain components require the removal of the
cabinet for repair access.

1. If the machine is in a freeze mode, perform a
manual harvest.

2. Remove all ice.

3. Drain reservoir.

4. Remove service panel and kick plate.

5. Remove back panel.

6. Disconnect electrical power.

7. Disconnect water and drain tubing.

8. Remove door.

9. Remove top panel.

10. Remove controller box cover.

11. Disconnect thermistor from controller, pull wire
back to suction line.

12. Remove curtain & hanger.

13. Locate elbows where water flows onto the
evaporator platen.

14. Pull clip up. Push inner elbow back and rotate it
until it points straight up, then push it back through
the hole in the back of the freezing compartment.

15. Pull water inlet elbow out of inner elbow.

June 2008

Page 30

SCCG50 & SCCP50

Service Manual

Electrical Shock
Hazard
.
Disconnect electrical
power before
beginning removal

Inlet

Elbow

Thermistor

Connector

Inner
Elbow

Inlet

Elbow

Clip

Advertising
This manual is related to the following products: