Components, Sccg30 & sccp30 service manual – Scotsman SCCG30 User Manual
Page 22
Advertising

Performance Information
Listed cycle times are after the 3rd consecutive cycle, will vary a minute or so, and will be longer for built
in units.
Harvest time is usually 2 minutes, longer in very
cold conditions.
Ice per cycle: 1/2 lb
Water drained / cycle: Varies by harvest cycle
length and purge setting. Typically about 3 pints.
Compressor amps: 2.9 - 3.1
September 2009
Page 21
SCCG30 & SCCP30
Service Manual
Freeze Cycle, Minutes
Air Temperature
100
90
80
70
60
50
Water
Temperature
100
60
46
45
43
42
40
90
54
44
42
40
38
36
80
45
40
38
37
35
34
70
40
37
35
33
32
30
60
31
30
27
26
24
23
50
24
23
22
21
20
19
40
23
21
20
19
18
18
Total Cycle, Minutes
Air Temperature
100
90
80
70
60
50
Water
Temperature
100
62
48
47
45
44
42
90
56
46
43
42
40
38
80
47
42
39
39
37
36
70
42
39
37
35
33
32
60
32
32
29
26
26
23
50
26
25
23
23
22
24
40
25
22
22
21
24
23
Advertising
This manual is related to the following products: