Components, Sccg30 & sccp30 service manual – Scotsman SCCG30 User Manual

Page 22

Advertising
background image

Performance Information

Listed cycle times are after the 3rd consecutive cycle, will vary a minute or so, and will be longer for built
in units.

Harvest time is usually 2 minutes, longer in very
cold conditions.

Ice per cycle: 1/2 lb

Water drained / cycle: Varies by harvest cycle
length and purge setting. Typically about 3 pints.

Compressor amps: 2.9 - 3.1

September 2009

Page 21

SCCG30 & SCCP30
Service Manual

Freeze Cycle, Minutes

Air Temperature

100

90

80

70

60

50

Water
Temperature

100

60

46

45

43

42

40

90

54

44

42

40

38

36

80

45

40

38

37

35

34

70

40

37

35

33

32

30

60

31

30

27

26

24

23

50

24

23

22

21

20

19

40

23

21

20

19

18

18

Total Cycle, Minutes

Air Temperature

100

90

80

70

60

50

Water
Temperature

100

62

48

47

45

44

42

90

56

46

43

42

40

38

80

47

42

39

39

37

36

70

42

39

37

35

33

32

60

32

32

29

26

26

23

50

26

25

23

23

22

24

40

25

22

22

21

24

23