Performance and Technical Specs

Overall:

•

Refrigerant: 4.5 oz R-134a

•

Compressor: Hermetic, 700 BTUH

•

Condenser: Forced draft

•

Fan blade: 3 blade, 6 inch

•

Evaporator: Stainless steel tube, copper coil
jacketed

•

Metering device: Cap tube

•

Auger drive: output speed 11 RPM

•

Water valve: Float in reservoir

•

Drain pump: Magnetic drive, controlled by
pressure switch

•

Bin control: Ultrasonic

Electrical Components:

•

Compressor - 2.9 to 3.1 amps

•

Fan motor

•

Auger motor, amp draw .4 to .5amp

•

Drain pump motor

•

Drain pump switch

•

Controller

•

Transformer

•

Water sensor

•

Ice level sensor

•

Membrane switch assembly

Control Timers

•

Power interruption, time to restart after power
restored: 2 minutes

•

Auger motor overload, time to restart: 4
minutes

•

Auger motor overload, restart window: 60
seconds

•

Auger motor low current, time to restart: 20
minutes

•

Auger motor low current, restart window: 60
seconds

•

Clean cycle time: 40 minutes total.

Note: During the auger motor restart window times,
there is no visible indication that the unit is in a
restart mode.

Light Blink Information

•

All blink once and repeat every 2 seconds:
Auger motor overload

•

All blink twice and repeat every 2 seconds:
Auger motor low current

•

All blink once and repeat every 10 seconds,
controller failure.

•

Water light blinks red: water supply failure

Controller Reset:

•

Cycle power off and on

Diagnostic Codes: No diagnostic codes are kept

Time to Clean indicator light standard interval to
switch light on is 6 months, it can be changed to
once per year or disabled.

To Adjust:

1. From Off, press and hold the On/Off and Clean
Reset Buttons for 5 seconds.

2. Press and Hold the Clean Reset Button for 5
seconds, then press On/Off. Then press On/off
again to cycle thru the settings:

Ice Making

Water

Time to
Clean

6 months

On

Off

Off

1 year

Off

On

Off

Disabled

Off

Off

On

Light will automatically go out after a few seconds
of inactivity. Press Time To Clean to lock in the
new setting.

Quick reset of time to clean light: Press and hold
the Clean Reset button for 3 seconds.

May 2011