Sensoray 826 User Manual
Page 76

Watchdog Timer
Timer stages
Number
3
Interval (per stage)
Programmable from 1 to 2
32
-1 * 20 ns (20 ns to ~85.9 s)
Output events
Stage 0: Fail-safe trigger, IRQ
Stage 1: NMI out via digital output, PCIe Fatal Error
Stage 2: Reset via digital output or onboard solid state relay (SSR)
Solid state relay
(Reset out)
On-state resistance (I
L
= 10mA)
20 ohms typical, 30
Ω
max.
Off-state leakage current
0.03 µA typical, 1.0 µA max.
Applied voltage (maximum)
200 V
Load current (maximum)
100 mA
Power and Environmental
Power
Input power
350 mA (+12V) and 450 mA (+3.3V), nominal, with no loads
Encoder power out
5 VDC ±5%, 400 mA max. (total for all encoders)
Temperature
Operating
0 to 70
º
C
Mating Connectors
(not included)
Counters
Sullins SFH210-PPPC-D13-ID-BK or equivalent (qty. 2)
Analog I/O
Sullins SFH210-PPPC-D25-ID-BK or equivalent (qty. 1)
Digital I/O
Sullins SFH210-PPPC-D25-ID-BK or equivalent (qty. 2)
826 Instruction Manual
71