Chapter 6: communication protocol, Page 21 – Smart Avi AVRouter User Manual

Page 21

Advertising
background image

AVRouter Manual Version 1.0

Page 21

Chapter 6: Communication Protocol

Chapter 6: Communication Protocol

Chapter 6: Communication Protocol

Chapter 6: Communication Protocol

Chapter 6: Communication Protocol

The command to make the end of CAT5 line receiver (SLRX-RX300) switch between its local and remote sources
is as follows;
<0xBE><0xEF><Frame Address><Reserved><CMD><DATA BYTES><BCC>

<0xBE><0xEF><Frame Address><Reserved><CMD><DATA BYTES><BCC>

<0xBE><0xEF><Frame Address><Reserved><CMD><DATA BYTES><BCC>

<0xBE><0xEF><Frame Address><Reserved><CMD><DATA BYTES><BCC>

<0xBE><0xEF><Frame Address><Reserved><CMD><DATA BYTES><BCC>
Where;
<0xBE>

<0xBE>

<0xBE>

<0xBE>

<0xBE>

always

always

always

always

always

0xBE

0xBE

0xBE

0xBE

0xBE

<0xEF>

<0xEF>

<0xEF>

<0xEF>

<0xEF>

always

always

always

always

always

0xEF

0xEF

0xEF

0xEF

0xEF

<Frame Address>

<Frame Address>

<Frame Address>

<Frame Address>

<Frame Address> Frame address. Set by Hex switch on unit or position in Rack frame.
<RESERVED>

<RESERVED>

<RESERVED>

<RESERVED>

<RESERVED>

always

always

always

always

always

0x00

0x00

0x00

0x00

0x00

<CMD>

<CMD>

<CMD>

<CMD>

<CMD> 50 (0x32)
<DATABYTES>

<DATABYTES>

<DATABYTES>

<DATABYTES>

<DATABYTES> is Two bytes <DESTINATION><SOURCE>

<DESTINATION><SOURCE>

<DESTINATION><SOURCE>

<DESTINATION><SOURCE>

<DESTINATION><SOURCE> 0L = Receiver LOCAL Video/Audio, 1 =

Receiver REMOTE Video/Audio
< B C C >

< B C C >

< B C C >

< B C C >

< B C C >
So if switching the Receiver on output 3 of Frame 2 to its local source send
<0xBE><0xEF><0x02><0x00><0x32><0x02><x00><0x63>

<0xBE><0xEF><0x02><0x00><0x32><0x02><x00><0x63>

<0xBE><0xEF><0x02><0x00><0x32><0x02><x00><0x63>

<0xBE><0xEF><0x02><0x00><0x32><0x02><x00><0x63>

<0xBE><0xEF><0x02><0x00><0x32><0x02><x00><0x63>

Get System Information

Get System Information

Get System Information

Get System Information

Get System Information
Cmd = 0xff
Databytes = NULL (none)

Unit will return a valid PSU as detailed above where Databytes are as follows

<product type>, <switch configuration> , <version>

Where Product Type =
1 Byte;
0 = SmartNet V
1 = SmartNet X
3 = SLX-TX550
4 = SLX-RX300

Where Switch configuration =
2 Bytes;
<inputs><outputs>

Where Version =

3 bytes
<Version><issue><release>

Appendix A: RS232/422 Converter and Comms Cable

Appendix A: RS232/422 Converter and Comms Cable

Appendix A: RS232/422 Converter and Comms Cable

Appendix A: RS232/422 Converter and Comms Cable

Appendix A: RS232/422 Converter and Comms Cable

RS232/RS422 Converter

RS232/RS422 Converter

RS232/RS422 Converter

RS232/RS422 Converter

RS232/RS422 Converter

A suitable RS232/RS422 product can be purchased from KK Systems

KK Systems

KK Systems

KK Systems

KK Systems in Brighton, East

Advertising