Console features – Smithco Spray Star 1100e Operator Manual User Manual
Page 18

16
Operation
CONSOLE FEATURES
This Console (PGM F) requires selection of US (acres); SI (hectares) or TU (1,000 sq ft) area
and SP2 (radar speed sensor). Hold SELF TEST key to view selection
A. POWER - Turns Console power OFF or ON. Turning Console OFF does not affect the data stored in
the computer.
B. FLOW CONTROL - Select manual or fully automatic control. This can automatically control two rates.
C. FLOW CONTROL - Manual override control provides capability for spot spraying.
D. Booms can be controlled individually, or all at once with MASTER ON/OFF Switch
E. Displays actual rate of application, calibration, and function data.
F. CE - Use like you do CE (clear entry) key on a calculator. This key is also used to select an area
base measurement of US (acres), SI (Hectares) or TU (1,000 sq ft).
GH.ENTER - Used only to enter the data into the Console.
Calibration Keys: (Top Row) Used to enter
Function Keys: (Bottom Row) Used to display data.
data into console to calibrate the system.
BOOM 1 CAL
Length of Boom 1
TOTAL AREA
Total Area Sprayed
BOOM 2 CAL
Length of Boom 2
FIELD AREA
Field Area Sprayed
BOOM 3 CAL
Length of Boom 3
FIELD VOLUME
Volume Applied to Field
SPEED CAL
determined by Speed Sensor
DISTANCE
Distance Traveled
METER CAL
Flow Meter Calibration Number
SPEED
Speed of Vehicle
VALVE CAL
Control Valve Response Time
VOLUME/TANK
Volume Remaining in Carrier Tank
RATE 1 CAL
Target Application Rate
TIME
24 hour clock (military time)
RATE 2 CAL
Target Application Rate
DATA MENU
Printer Option
SELF TEST
Simulates Vehicle Speed