371.6.16 SX022270 SX-S Extension module

372. This module contains the SX022241 Stereo Analog Level & Phase Meter, plus the monitoring and communication functions, (including MS decoding). It is shipped with

the necessary Neutrik 6-pin chassis connector (SX860180) for connection to the SX-S Boom Box (SX022260) and the 12-pin chassis connector (SX860208) for

connection to the SX-S Extension Box. (SX022251). It also includes the necessary mounting hardware and connectors for installation in an existing SX-S mixer.

373.  

374.6.17 SX022251 SX-S Extension box

375. The Extension Box is a signal distribution box (300mm x 56mm x 40mm) shipped with 1,5m of cable with the necessary connectors. Various connectors are installed in

the distribution box to interface the SX-S mixer with the Extension Module directly with the Stelladat, Nagra 4.2, and Nagra IVS, or other equipment.

376.  

377.6.18 SX022260 SX-S Boom box

378. This small box connects to the SX-S Extension Module with an optional cable (SX922120). The box incorporates a 1/4" headphone socket, a 3 pin XLR socket for a

talkback microphone and a switch to call the mixer's operator with a "Roll" indicator.

379.  

380.6.19 SX922120 SX-S Boom box cable

381. 2-pair shielded cable 10 meters in length (longer on request) with 6 pin XLR connectors on each end to connect the Boom Box with the SX-S Extension Module.

382.  

383. RETURN TO TABLE OF CONTENTS

384.

385.  

386.

7. INSTALLATION INSTRUCTIONS

for SX022270 SX-S Extension Module

387.  

388.7.1 Equipment:

022270 SX-S Extension Module

SX922130 Internal cable extension module - Extension Box

SX922140 Internal cable extension module - Boom Box

SX860141 Socket 1/4'' with 150mm shielded cable and Dubox case

SX8600342 6 Pin socket connector

SX860500 6 Pin socket connector with 300mm flat cable

SX942291 Blank Panel Jack 4.4 (2x)

SX980124 Allen head screw M2,5x8 (4x)

SX980123 Allen head screw M2,5x6 (4x)

SX986420 Washer ribbed M2,5 (8x)

SX981134 Conical head screw M3x8 (4x)

SX642403 24 kOhms 1% R0805 Resistor (2x)

SXS351220 22pF 1% C0805 (1x)

SXS644990 49,9 Ohms 1% R0805 Resistor (1x)

SXS641503 15 kOhms 1% R0805 Resistor (1x)

SX860131 Bantam mini-jack pre-wired (1x)

SX140002 NPN-Transistor BC 550 C

389. When installing an SX022270 SX-S Extension Module in an SX-S mixing console with serial-number 16585 or lower R-64 and R-65 on the extension module operator

board need to be replaced by 24kOhms 1% SMD R0805.

390.  

391.7.2 Procedure

392. On the Master Board (solder side) solder the 6 conductors of the ribbon cable(see PCB Layout)

393. Change Q1 (BC337) on the Masterboard with BC 550C (SX140002).

394. Mount the 12-pin Hirose socket in place of the last Input's 3-pin Neutrik.

395. Install the 6-pin Neutrik socket next to the 12-pin Hirose socket.

396. Install the Extension module beside the master board and connect the wires asindicated on the PCB Layout. Do not forget to install the additional 26-pin connector on

the SX-S10 ribbon cable.

397. SX-S 10

: Disconnect the Aux. XLR 3-pin male and replace it with SX860141,socket 1/4'' with 150mm shielded cable and Dubox case.

398. SX-S 6 SX-S 8

: Remove the existing 1/4'' Jack, unsolder the connections on the Masterboard and reconnect to the Bantam Jack with cable provided. Install the

SX860141, socket 1/4'' with 150mm shielded cable and Dubox case.

399. Click here for Illustration of INTERNAL connections, ajustments and switches

400. Click here for Master Module PCB Layout

401. NOTE:The ribbon cable connects to the PCB (from Left to right) Yellow - Brown - Orange - Green - Red - Blue.

402. Connections of the 6 pole Flatcable

403. Brown Cable

404. 1

405. PFL-BUS-left

406. Connected to pin No 1 OP-7

407. Red Cable

408. 2

409. MASTER-BUS-right

410. Connected to pin No 1 OP-3

411. Orange Cable

412. 3

413. PFL-BUS-right

414. Connected to pin No 7 OP-7

415. Yellow Cable

416. 4

417. Auxiliary BUS

418. Connected to cursor Aux

potentiometer

419. Green Cable

420. 5

421. PFL Control-CDE (sense)

422. Connected to point R-6/R-5/collector

of Q1

423. Blue Cable

424. 6

425. MASTER-BUS-left

426. Connected to pin No 7 OP-3

Advertising