LTU SERIES SPECIFICATIONS

Model

Model

Model

Model

No.

No.

No.

No.

Input

Input

Input

Input,,,,

Btu/hr

Btu/hr

Btu/hr

Btu/hr

Flue Restrictor

Flue Restrictor

Flue Restrictor

Flue Restrictor Plate

Plate

Plate

Plate

I.D. &

I.D. &

I.D. &

I.D. & Part #

Part #

Part #

Part #

Orifice Size

Orifice Size

Orifice Size

Orifice Size

Minimum *

Minimum *

Minimum *

Minimum *

Mounting Height

Mounting Height

Mounting Height

Mounting Height

High

High

High

High

Low

Low

Low

Low

Natural Gas

Natural Gas

Natural Gas

Natural Gas

Propane Gas

Propane Gas

Propane Gas

Propane Gas

@

@

@

@

Horizontal

Horizontal

Horizontal

Horizontal

@

@

@

@

45º Angle

45º Angle

45º Angle

45º Angle

LTU 80

80,000

50,500

1-1/2” #42741050

#19

(0.166)

#38

(0.102)

13 ft.

12 ft.

LTU 90

90,000

57,000

1-1/2” #42741050

#16

(0.177)

#36

(0.106)

13 ft.

12 ft.

LTU 100 100,000 63,000

1-5/8” #42741060

#14

(0.182)

#33

(0.113)

13 ft.

12 ft.

LTU 110 110,000 69,500

1-3/4” #42741070

#10

(0.194)

#31

(0.120)

14 ft.

13 ft.

LTU 120 120,000 76,000

1-3/4” #42741070 13/64 (0.203)

1/8

(0.125)

14 ft.

13 ft.

LTU 125 125,000 80,000

1-7/8” #42741080

#5

(0.206)

#30

(0.129)

14 ft.

13 ft.

LTU 130 130,000 82,000

1-7/8” #42741080

#4

(0.209) 3.3mm (0.130)

14 ft.

13 ft.

LTU 140 140,000 88,500 2-1/32” #42741090 5.5mm (0.216)

#29

(0.136)

15 ft.

14 ft.

LTU 150 150,000 95,000 2-1/32” #42741090 5.7mm (0.224)

#28

(0.140)

15 ft.

14 ft.

LTU 160 160,000 100,000 2-1/4” #42741100 5.8mm (0.228)

#27

(0.144)

15 ft.

14 ft.

LTU 175 175,000 110,000 2-1/4” #42741100

“C”

(0.242) 3.8mm (0.150)

15 ft.

14 ft.

LTU 180 180,000 114,000 2-1/4” #42741100

“C”

(0.242)

#24

(0.152)

18 ft.

17 ft.

LTU 200 200,000 125,000 2-3/8” #42741130

“F”

(0.257)

#21

(0.159)

18 ft.

17 ft.

LTU 225 225,000 146,000 2-1/2” #42741140 6.9mm (0.272)

#18

(0.170)

20 ft.

19 ft.

LTU 250 250,000 162,000 2-3/4” #42741150

“K”

(0.281) 4.5mm (0.177)

20 ft.

19 ft.

* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.

Type

Type

Type

Type

Gas

Gas

Gas

Gas

Gas Pipe

Gas Pipe

Gas Pipe

Gas Pipe

Connection

Connection

Connection

Connection

Tube

Tube

Tube

Tube

Diameter

Diameter

Diameter

Diameter

Flue

Flue

Flue

Flue

Connection

Connection

Connection

Connection

1

1

1

1

Fresh Air

Fresh Air

Fresh Air

Fresh Air

Connection

Connection

Connection

Connection

Electrical

Electrical

Electrical

Electrical

Supply

Supply

Supply

Supply

Current

Current

Current

Current

Rating

Rating

Rating

Rating

Natural

or Propane

½” MPT

(Male)

4”

4” Round

6” Round

120 Volt, 60Hz,

1 Phase

2.6 Amp

1

LTU 180-250: 6” round. See Section 17.0) for vent sizes and limitations.

Fuse

Fuse

Fuse

Fuse Rating:

Rating:

Rating:

Rating:

Ignition Syste

Ignition Syste

Ignition Syste

Ignition System (direct spark):

m (direct spark):

m (direct spark):

m (direct spark):

In-line: 2 Amp 250V

(for 24V Circuit)

30 second pre-purge period


7.0)

LTU SERIES PACKING LIST

A.

A.

A.

A.

Control/Draft Induce

Control/Draft Induce

Control/Draft Induce

Control/Draft Inducer Package

r Package

r Package

r Package

Part Description

Part Description

Part Description

Part Description

QTY

QTY

QTY

QTY

Control Box Assembly .............................................................................................................................. 1
Draft Inducer & Junction Box Assembly ................................................................................................ 1
Flue Restrictor Plate (See Section 6.0) for plate I.D. and part no.) ................................................... 1
4” x 6” Starting Collar

1

(#42892009) Supplied with LTU 180-250 ................................................. 1

Control Fastener Kit (#42907010) ....................................................................................................... 1

Containing: #8-32 Screws & Nuts (#02166010 & #02127030) .......................................... 2

¼ - 20 Locknuts (#02167010) .............................................................................. 6

Tube Flange Gasket (#42921000) ...................................................................................................... 2
Installation & Operation Instructions (#43155040) .......................................................................... 1
Gas connector, 5/8” OD x 36”

2

(#30302360) .................................................................................... 1

1

4-inch Starting Collar (#40504020) supplied with LTU 80-175 models.

2

LTU 225 and 250 models using Gas Connector, 1” OD x 36” (#30302361).

Advertising