Page 41
Function: Monitor Output Level - Normal
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1
st
Byte of Studio Tech ID
3
00H
2
nd
Byte of Studio Tech ID
4
56H
3
rd
Byte of Studio Tech ID
5
03H
Product ID (Model 58)
6
03H
Function, Monitor Output Level - Normal
7
nnH
Monitor Output Level, MSB, range 00-7F
8
0nH
Monitor Output Level, LSB, range 0-1
9
F7H
EOX, End of System Exclusive
Notes: Control console sends new value each time monitor output level is changed.
Monitor output level is 8-bit precision, spread over two MIDI bytes: 00H 00H
lowest; 7FH 01H highest. MIDI byte 7 is monitor output level bits 2-8; MIDI
byte 8 is monitor output level bit 1.
Dim function is performed by control console and is sent using monitor output
level command.
This function is in effect only when monitor output channel status is on and bypass
status is normal.