MAINTENANCE SCHEDULE

TROUBLESHOOTING CHART

General

Engine assembly, screws and nuts

Visual inspection for damage and tightness.
Check for general condition and security.

After each refueling

Control lever
I-O switch

Functional check
Functional check

Daily

Air filter
Cooling air duct
Cutting tool
Idling speed

To be cleaned
To be cleaned
Check for damage and sharpness
Inspect (Cutting tool does not rotate)

Weekly

Spark plug
Muffler

Inspection, replace if necessary
Check and clean the opening if necessary

Quarterly

Suction head
Fuel tank

To be replace
To be cleaned

Yearly
(Long Term)

Fuel tank
Carburetor

Empty fuel tank
Operate until engine stops

Trouble

System

Observation

Cause

Engine does not start or
hard to start

Ignition system

Ignition spark O.K.

Failure in fuel supply or compression system, mechanical defect

No ignition spark

I-O switch operated, wiring fault or short circuit, spark plug or
connector defective, ignition module faulty

Fuel supply

Fuel tank filled

Wrong choke position, defective carburetor, fuel supply line bent
or blocked, dirty fuel

Compression

No compression when pulled over Cylinder bottom gasket defective, Crankshaft seals damaged,

Cylinder or piston rings defective or improper sealing of spark
plug

Mechanical fault

Starter not engaging

Broken starter spring, broken parts inside the engine

Warm start problem

Tank filled
Ignition spark

Carburetor contaminated or damaged. Clean or replace.

Engine starts but soon
stops

Fuel supply

Tank filled

Incorrect idle-adjustment,
Carburetor contaminated
Defective tank, fuel supply line interrupted, cable or I-O switch
defective.

Insufficient performance

Several systems

Poor engine idling

Air filter contaminated, carburetor contaminated, muffler
clogged, exhaust duct in the cylinder clogged