Super Systems MGA6000 User Manual
Page 39

SSi Manual #4563 Rev. D Page 39 Multi-Gas Model 6000
2021
read SPI
2022
SPI data counter, high byte
2023
SPI store state 0 = normal operation (store)
1 = receiving data from boss, 2 = OK to send to Cell, 4 = sending to cell
2024
timer on SPI response, 10ms inc
2025
indicates
SPI
responded
2026
Last
command
used
2027
Result of the last command
* Registers 2028 to 2029 not used
* Data sent by IR cell in master mode
2030
decimal place //debug
2031
gas reading
* calc structure
2032
deg C (2032 - 2033)
2034
volts (2034 - 2035)
2036
atten (2036 - 2037)
2038
zero_volts_tc (2038 - 2039)
2040
span_volts_tc (2040 - 2041)
2042
atten_tc (2042 - 2043)
2044
curve_in (2044 - 2045)
* cal structure
2046
degCZ (2046 - 2047)
2048
degCS (2048 - 2049)
2050
Zero_volts (2050 - 2051)
2052
Span_Volts (2052 - 2053)
2054
ztc (2054 - 2055)
2056
stc (2056 - 2057)
2058
zero_offset (2058 - 2059)
2060
span_target (2060 - 2061)
2062
Command
2063
Command
result
* curve structure
2064
c_dummy (2064 - 2065)
2066
coeff_0 (2066 - 2067)
2068
coeff_1 (2068 - 2069)
2070
coeff_2 (2070 - 2071)
2072
coeff_3 (2072 - 2073)
2074
coeff_4 (2074 - 2075)
2076
coeff_5 (2076 - 2077)
2078
coeff_6 (2078 - 2079)
2080
coeff_7 (2080 - 2081)
* EEROM structure
2082
software revision (2082 - 2090)
* Define date_of_cal
2091
Filter
2092
span_offset (2092 - 2093)
* Registers 2094 to 2098 not used
* calculated values
2099
gas_value_adj
2100
copy of PIC_com_stat
2101
A/D Input 0 reading