6. TECHNICAL

CHARACTERISTICS

• Mounting:

Vertical / Side mounting.

• Fittings:

DIN 2501 DN65 PN 16flanges

Others on demand

• Minimum liquid density:

0.45 kg/l

• Liquid viscosity:

maximum 3.000 mPa.s

• Repeatability:

±3 mm of the level .

• Materials:

EN 1.4404 (AISI-316L)

On demand: PVC, PP, PTFE, PVDF

• Electrical housing:

Metal alloy aluminium

On demand: EN 1.4401 (AISI-316), PP, PTFE

• Pressure:

PN16 (PN10 for plastic)

On demand: PN40 ... PN400

• Liquid temperature:

Depends on the following table

(1) The liquid working temperatures are given for an ambient temperature of 20ºC.

• Ingress protection

IP65

• Limit switch characteristics

Complies with 97/23/EC Directive for pressure equipment.

This equipment is considered as being a pressure accessory and NOT a safety accessory
as defined in the 97/23/EC Directive, Article 1, paragraph 2.1.3.

Materials

Liquid temperature range

Maximum product

temperature (1)

+ thermal housing

EN 1.4404 (AISI-316L)

-50ºC…...150º C

300º C

PVC

0ºC…..50º C

-------

PP

-20ºC…..90ºC

-------

PTFE

-20ºC…..150º C

-------

PVDF

-20ºC.....150º C

-------

Switch

System

Characteristics

Maximum

ambient

temperature

AMM

Snap action switch

C/NO/NC

250 V max.

3 A max.

-25 to +85 ºC

AMD

Inductive NAMUR

max.. I > 2.2 mA

min. I < 1.1 mA

-25 to +85 ºC

AMR

Reed switch

C/NO/NC

250 V max.
0.5 A max.

-25 to +85 ºC

AMP

Pneumatic

switch

2 ... 6 bar

0 to +50 ºC

5